{"product_id":"landyindus-laydown-concrete-kibble-bottom-discharge-for-column-narrow-shutter-pours-1-0-2-0m-ws-ckl-series","title":"LANDYINDUS Laydown Concrete Kibble Bottom Discharge for Column \u0026 Narrow Shutter Pours 1.0–2.0m³ WS-CKL Series","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003ePouring narrow columns, core walls, and tight shutters? The LANDYINDUS Laydown Concrete Kibble fills horizontally at ground level and lifts vertically to pour 1.0–2.0m³ batches with precision.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe LANDYINDUS Heavy Duty Laydown Concrete Kibble (Lay Down Concrete Skip Bucket) is specially engineered for high-precision concrete placement in narrow shuttering, precast molds, columns, and confined formwork where standard upright buckets cannot reach. Featuring a unique two-stage operation, the kibble rests flat on the ground for low-profile transit mixer filling, then tilts into a vertical orientation when hoisted by a crane for pin-point bottom discharge.\u003c\/p\u003e\n\u003ch3\u003eCore Selling Points\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHorizontal Fill \u0026amp; Vertical Pour:\u003c\/strong\u003e Lays flat on the ground for fast, low-clearance discharge directly from ready-mix trucks, then hoists vertically for controlled pouring.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePrecision Clamshell Gate \u0026amp; 1m Hose:\u003c\/strong\u003e Lever-actuated bottom clamshell gate paired with a standard 1m flexible hose (200mm diameter) directs slurry accurately into dense rebar cages.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeavy-Gauge 6mm Steel Shell:\u003c\/strong\u003e Fabricated from 6mm high-strength structural steel plate with rated Safe Working Loads of 3,000–4,500 kg to endure continuous high-volume civil works.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStable Bolt-On Ground Frame:\u003c\/strong\u003e Supplied as standard with a heavy-duty bolt-on cradle frame ensuring firm, stable positioning while charging concrete at ground level.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003ctable border=\"1\" style=\"width: 100%; border-collapse: collapse;\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eType\u003c\/th\u003e\n\u003cth\u003eSWL \/ kg\u003c\/th\u003e\n\u003cth\u003eDimension (L×W×H) \/ mm\u003c\/th\u003e\n\u003cth\u003eMain Plate Thickness \/ mm\u003c\/th\u003e\n\u003cth\u003eVolume \/ m³\u003c\/th\u003e\n\u003cth\u003eWeight \/ kg\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eWS-CKL1.0TRA\u003c\/td\u003e\n\u003ctd\u003e3000\u003c\/td\u003e\n\u003ctd\u003e1475×1385×3130\u003c\/td\u003e\n\u003ctd\u003e6\u003c\/td\u003e\n\u003ctd\u003e1.0\u003c\/td\u003e\n\u003ctd\u003e503\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWS-CKL1.5TRA\u003c\/td\u003e\n\u003ctd\u003e4000\u003c\/td\u003e\n\u003ctd\u003e1580×1530×3315\u003c\/td\u003e\n\u003ctd\u003e6\u003c\/td\u003e\n\u003ctd\u003e1.5\u003c\/td\u003e\n\u003ctd\u003e570\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWS-CKL2.0TRA\u003c\/td\u003e\n\u003ctd\u003e4500\u003c\/td\u003e\n\u003ctd\u003e1705×1695×3500\u003c\/td\u003e\n\u003ctd\u003e6\u003c\/td\u003e\n\u003ctd\u003e2.0\u003c\/td\u003e\n\u003ctd\u003e658\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eTechnical Drawing\u003c\/h2\u003e\n\u003cdiv\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0808\/6195\/4293\/files\/DM_20260911140941_003.jpg?v=1789107026\" alt=\"\"\u003e\u003c\/div\u003e\n\u003ch2\u003e⚠️ Safety \u0026amp; Compatibility Warnings\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eTilt \u0026amp; Hoist Rotation Arc:\u003c\/strong\u003e When hoisting from horizontal laydown to vertical flight, the bucket pivots through a dynamic arc. Keep all personnel strictly clear of this rotation radius.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeavy Slurry Limits:\u003c\/strong\u003e Wet concrete weighs approx. 2,400 kg\/m³. Strictly calculate volume and never exceed the certified SWL (3,000kg for 1.0m³; 4,000kg for 1.5m³; 4,500kg for 2.0m³).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOverhead Exclusion \u0026amp; Hose Guiding:\u003c\/strong\u003e Operators guiding the flexible discharge hose must position themselves beside the pour and never stand directly beneath the suspended kibble.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLevel Ground Filling:\u003c\/strong\u003e Ensure the bolt-on support frame rests on firm, compacted, level ground prior to receiving concrete from the transit mixer.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"LANDYINDUS","offers":[{"title":"Default Title","offer_id":48838762397941,"sku":"WS-CKL1.0TRA","price":0.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0808\/6195\/4293\/files\/DM_20260911140941_001.jpg?v=1789107074","url":"https:\/\/www.landyindus.com\/products\/landyindus-laydown-concrete-kibble-bottom-discharge-for-column-narrow-shutter-pours-1-0-2-0m-ws-ckl-series","provider":"landyindus","version":"1.0","type":"link"}